PlanGen8308 Old Deer Trl, Raleigh, NC

SITE INTELLIGENCE · LIVE

8308 Old Deer Trl, Raleigh, NC

Internal ID: LOCAL · PROJ-d1b

The property, explained layer by layer from its real backend evidence. Every layer names what it rests on and what it cannot establish — mapped context is not a survey, and none of this forecasts a decision.

Address
8308 Old Deer Trl, Raleigh, NC
Jurisdiction
RA
Parcel
1707598141

Matched to a specific parcel

This address matched a specific parcel. Review what was checked below.

Version 2 · checked 2026-08-26

Checked

within Raleigh corporate limits

Planning jurisdictionRAFrom a public record
Checked

resolved to one parcel

Parcel ID (PIN)1707598141From a public record
Site address on file8308 OLD DEER TRLFrom a public record
Deed acreage0.29From a public record
Checked

resolved to one zoning record

DistrictR-4From a public record
Conditional district?falseFrom a public record
Checked

all 12 overlay layers answered

Checked all 12 of the City's overlay layers — none found at this address point.

Checked
Deed acreage (county record)0.29From a public record
Checked

8 rows from the retrieved UDO Sec. 2.2.1 table

Area (min)10,000 sfCONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.
Lot Width (min)65'CONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.
Depth (min)100'CONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.
Density (max)No per-acre cap — density governed by minimum lot areaAFFIRMATIVE NO REQUIREMENTThe ordinance was checked and deliberately imposes no limit here — a positive finding, not missing data.
Principal building setback from primary street (min)20'CONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.
Principal building setback from side street (min)20'CONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.
Principal building setback from side lot line (min)10'CONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.
Principal building setback from rear lot line (min)30'CONDITIONAL REQUIREMENTThe ordinance sets this number, but whether it governs this parcel depends on facts not yet resolved.

Every number above has a status. None is a final, verified requirement without professional or official confirmation.

Not available from current sources

Building footprints are not persisted in this enrichment snapshot. PlanGen retrieves them live from the City of Raleigh Building_Footprints source at map-render time when the geometry feature is enabled in the deployment; source-use rights were confirmed by the owner on 2026-08-25 (see Data sources & notices). This is not a finding about whether a structure exists on the parcel.

Could not reach the source right now

This public source could not be reached just now (it may have returned too much data, or been temporarily down). This is not a finding about the property — try checking again later.

Flood zoneThe mapped designation at this point could not be determined from the current source this run. The parcel-scale relation could not be determined on this record.
Could not reach the source right now

fema flood_observation: the service answered 504. Server-side and temporary; it says nothing about what the service holds.

Mapped context only; not a BFE, not a survey, not a compliance conclusion.

PUBLIC-RECORD SITE DIAGRAM

N8308 Old Deer Trl, Raleigh, NCR-4

CONDITIONAL — setback envelope shown above depends on facts not resolved from the public record (see Dev Standards / Setbacks below).

8 public source records · wake-county-raleigh-nc · as of 2026-08-26

Assembled from public records. Not a boundary survey. Not permit approval. Not construction staking. Professional verification may be required.

  • wake-county-raleigh-ncgeocode:address_locatoras of 2026-08-26
  • us-census-geocoderonelineaddress:address_matchas of 2026-08-26
  • wake-county-raleigh-ncobserve:parcelas of 2026-08-26
  • wake-raleigh-admin-contextobserve:corporate_limitsas of 2026-08-26
  • wake-raleigh-admin-contextobserve:planning_jurisdictionsas of 2026-08-26
  • wake-county-raleigh-ncobserve:zoning_raleighas of 2026-08-26
  • wake-county-raleigh-ncgeometry:parcelas of 2026-08-26
  • wake-county-raleigh-ncurban_form_frequent_transit_area:parcel_relationas of 2026-08-26
  • UDO setback applicability depends on facts (use type, lot type, infill comparative sample) not resolvable from GIS records

    a site plan review by the City of Raleigh Development Services Department, or a licensed design professional

No issues surfaced above does not mean the property has no issues — it means these specific public sources did not report one. PlanGen is not the authority having jurisdiction and does not forecast a permit decision.

No evidence-linked findings are recorded against a site-intelligence layer for this project yet — separate from the property record above, which reflects what public records show regardless of whether any finding has been made.

LOCAL LAB LIVE DATA · backend session, not a public fixture